Go back

How can I disable the heater after unattended printing is finished?

Set “”STANDBY” time” and “”OFF TIME”” of the heater temperature setting.* This information is valid only during printing.

“”STANDBY” time” sets the duration before entering the preheated state.
The preheated state has a temperature lower than the preset temperature of each heater by 3°C to 5°C.

“”OFF TIME”” sets the duration before turning off the heaters.
The machine enters each state after staying for the time set as above.

* The “STANDBY” or “OFF state” will go back to the preset temperature when receiving print data or a key operation.

“STANDBY”time (Heater Standby) “OFF TIME” (heater OFF) Meaning
Zero Zero Heater turns off immediately after printing is finished
None None Heater remains on after printing is finished
None Zero Heater turns off immediately after printing is finished
None 10~ Heater turns off 10 minutes after printing is finished, without entering the preheated state.
Zero None Pregeating starts immediately after printing is finished. Heater remains on even after entering the preheated state.
Zero 10~ Preheating starts immediately after printing is finished. Heater turn off 10 minutes after entering the preheated state.
10~ None Preheating starts immediately after printing is finished. Heater turn off 10 minutes after entering the preheated state.
10~ Zero Preheating starts immediately after printing is finished. Heater turns off immediately after entering the preheated state.
10~ 10~ Preheating starts immediately after printing is finished.Heater turns off 10 minutes after entering the preheated state.

When setting heater time on the JV34-260 main unit

For how to set the heater time on the JV34-260 main unit,see “Operation Manual” -> “Extended Functions” -> “Changing the Set Values of the Heaters.”

* To use the values set on the JV34-260 main unit panel, select [Printing Condition] -> [Print Mode] in the job editor of the RasterLinkPro series. Then, select [Panel Setting] in “Heater Standby” and “Heater OFF”.

When setting heater time in the RasterLinkPro series

For how to set the heater time in the RasterLinkPro series, select [Printing Condition] -> [Print Mode] in the job editor. Select [User Definition] in “Heater Standby” and “Heater OFF”, then set the time.